Customization: | Available |
---|---|
Application: | Communication |
Type: | Single-mode Fiber |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Fiber count | 1~144 | |||||||
OD of Loose tube | 2.0±0.1 | |||||||
(mm) | ||||||||
Max fiber | 12 | |||||||
count/tube | ||||||||
NO. of | Tube | 1~12 | ||||||
NO. of | Filler | 1~12 | ||||||
FRP/Coat(mm) | 24F | 48F | 96F | 144F | ||||
2.1 | 2.1 | 2.6(ADD PE3.2) | 2.6(ADD PE5.8) | |||||
Water blocking | Water blocking yarn and tape | |||||||
material | ||||||||
Reinforced | Aramid yarn | |||||||
materials | ||||||||
PE sheath | 1.5 | |||||||
Thickness(mm) | ||||||||
OD of cable | 10.5 | 10.5 | 11.5 | 14 | ||||
(mm) | ||||||||
Operating temperature | -40ºC~+60ºC |
Store/Transport temperature | -50ºC~+70ºC |
Installation temperature | -20ºC~+60ºC |
Items | UNITS | SPECIFICATION |
Fiber type | - | G652D |
Attenuation | dB/km | ≤ 0.36 at 1310nm |
≤ 0.22 at 1550nm | ||
≤ 3.5 at 1310nm | ||
Chromatic Dispersion | ps/nm.km | ≤ 18 at 1550nm |
≤ 22 at 1625nm | ||
Zero Dispersion Slope | ps/nm2.km | ≤ 0.092 |
Zero Dispersion Wavelength | nm | 1300 ~ 1324 |
PMD (M=20, Q=0.01%) | ps/√km | ≤ 0.2 |
Cut-off Wavelength (lcc) | nm | ≤ 1260 |
Attenuation vs. Bending | dB | ≤ 0.1 at 1625nm |
(60mm x100turns) | ||
Mode Field Diameter | mm | 9.2 ± 0.4 at 1310nm |
Core-Clad Concentricity | mm | ≤ 0.5 |
Cladding Diameter | mm | 125±1 |
Cladding Non-circularity | % | ≤ 0.8 |
Coating Diameter | mm | 245±5 |
Proof Test | Gpa | ≥ 0.69 |
NO. | ITEMS | TEST METHOD | ACCEPTANCE CRITERIA | |||
Tensile | #Test method:IEC 60794-1-E1 | -. Attenuation increment@1550nm: | ||||
-. Long-tensile load:700N | ≤0.1dB | |||||
1 | Loading Test | |||||
-. Short-tensile load:1500N | -. No jacket cracking and fiber | |||||
-. Cable length:≥50m | breakage | |||||
#Test method:IEC 60794-1-E3 | -. Attenuation increment@1550nm: | |||||
2 | Crush | -.Long load:300 N/100mm | ≤0.1dB | |||
Resistance Test | -.Short load:1000 N/100mm | -. No jacket cracking and fiber | ||||
Load time:1 minutes | breakage | |||||
#Test method:IEC 60794-1-E4 | -. Attenuation increment@1550nm: | |||||
-.Impact height:1m | ||||||
Impact | ≤0.1dB | |||||
3 | -.Impact weigh: 450g | |||||
Resistance Test | -. No jacket | cracking | and | fiber | ||
-.Impact point:≥5 | ||||||
breakage | ||||||
-.Impact frequency:≥3/point | ||||||
#Test method:IEC 60794-1-E6 | ||||||
-.Mandrel diameter:20D (D = | -. Attenuation increment@1550nm: | |||||
4 | Repeated | cable diameter) | ≤0.1dB | |||
Bending | -.Subject weight:15kg | -. No jacket cracking and fiber | ||||
-.Bending frequency:30 times | breakage | |||||
-.Bending speed:2s/time | ||||||
#Test method:IEC 60794-1-E7 | -. Attenuation increment@1550nm: | |||||
-.Length:1m | ||||||
≤0.1dB | ||||||
5 | Torsion Test | -.Subject weight:25kg | ||||
-. No jacket | cracking | and | fiber | |||
-.Angle:±180 degree | ||||||
breakage | ||||||
-.Frequency:≥10/point | ||||||
Water | #Test method:IEC 60794-1-F5B | |||||
-.Height of pressure head:1m | -. No leakage | through | the | open | ||
6 | Penetration | |||||
-.Length of specimen:3m | cable end | |||||
Test | ||||||
-.Test time: 24 hours | ||||||
#Test method:IEC 60794-1-F1 | -. Attenuation increment@1550nm: | |||||
Temperature | -.Temperature steps:+20ºC, | |||||
7 | -40ºC,+70ºC,+20ºC | ≤0.1dB | ||||
Cycling Test | -. No jacket | cracking | and | fiber | ||
-.Testing Time:24 hours/step | ||||||
breakage | ||||||
-.Cycle index:2 | ||||||
Drop | #Test method:IEC 60794-1-E14 | |||||
8 | Performance | -.Testing length:30cm | -. No filling compound drop out | |||
-.Temperature range:70±2ºC |