Customization: | Available |
---|---|
Application: | Communication |
Type: | Single-mode Fiber |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
No. | 1 | 2 | 3 | 4 | 5 | 6 |
Color | Blue | Orange | Green | Brown | Gray | White |
No. | 7 | 8 | 9 | 10 | 11 | 12 |
Color | Red | Black | Yellow | Purple | Pink | Aqua |
SN | Item | Unit | Value |
1 | No. of fibers | count | 8 |
2 | Tube diameter(±5%) | mm | 2.0 |
3 | Tube per cores | Fibers | 8 |
4 | Strength member | mm | 0.8 |
5 | Cable diameter(±5%) | mm | 11.5 |
6 | Out Jacket thickness | Mm | 1.8 |
7 | Inner Jacket thickness | MM | 0.6 |
8 | Cable weight(±10%) | kg/km | 120 |
Item | Test Method | Acceptance Condition |
Tensile Strength IEC 794-1-2-E1 |
- Load: Short term tension - Length of cable: about 50m |
- Fiber strain £ 0.6% - No fiber break and no sheath damage. |
Crush Test IEC 60794-1-2-E3 |
- Load: Short term crush - Load time: 1min |
- Loss change £ 0.1dB@1550nm - No fiber break and no sheath damage. |
Impact Test IEC 60794-1-2-E4 |
- Points of impact: 3 - Times of per point: 1 - Impact energy: 1J |
- Loss change £ 0.1dB@1550nm - No fiber break and no sheath damage. |
Repeated Bending IEC 60794-1-2-E6 |
- Bending radius: 20 x OD - No. of cycle: 30 |
- Loss change £ 0.1dB@1550nm - No fiber break and no sheath damage. |
Torsion IEC 60794-1-2-E7 |
- Length: 1m - Twist angle: ±180° - No. of cycle: 10 |
- Loss change £ 0.1dB@1550nm - No fiber break and no sheath damage. |
Compound flow IEC 60794-1-2-E14 |
- Length: 30cm - Temperature:70 oC±2 oC - Period:24h |
- No outflow or dripping |
Temperature Cycling IEC 60794-1-2-F1 |
- Temperature:+20oC→-40oC→+60oC →+20oC - Time of each step: 12h - Number of cycle: 2 |
- Loss change £ 0.1dB/km@1550nm - No fiber break and no sheath damage. |